H 588 Oregon State University Industrial Crystalline Silica Presentation Instructions: You will be responsible for presenting information from a method, pr

H 588 Oregon State University Industrial Crystalline Silica Presentation Instructions: You will be responsible for presenting information from a method, provided by OR OSHA, that you drew from a “hat”. Use internet resources to learn more about the agent being sampled, how it is sampled and how it is analyzed. You will prepare a 5-10-minute presentation for the class covering the following items:

Description of:

Don't use plagiarized sources. Get Your Custom Essay on
H 588 Oregon State University Industrial Crystalline Silica Presentation Instructions: You will be responsible for presenting information from a method, pr
Just from $13/Page
Order Essay

The agent. (2 points)respirable

Occupation or workplace setting potentially exposed to the agent/hazard. (2 points)

Sampling technique is used in the method. (3 points)

Analytical technique is used in the method. (3 points) H588: Applied Occupational Safety and Health
Homework 3: Industrial Hygiene Sampling and Analytical Methods – Presentation (10 pts)
Due: PPT prepared on May 13 submitted in Canvas before class, to be presented during zoom
session on this date.
Background: To prepare for learning about industrial hygiene, you will become familiar with the
different sampling and analytical techniques used in a consultative and regulatory agency. These are
methods provided by OR OSHA. In the past, we have visited the OR OSHA Occupational Health lab,
where you would have seen this equipment and meet with the lab manager and industrial hygienist who
could explain and demonstrate the use of these techniques. Oregon is one just a few states that has such
a lab so we are lucky to have the facility.
Instructions: You will be responsible for presenting information from a method, provided by OR OSHA,
that you drew from a “hat”. Use internet resources to learn more about the agent being sampled, how it
is sampled and how it is analyzed. You will prepare a 5-10-minute presentation for the class covering
the following items:
Description of:
The agent. (2 points)
Occupation or workplace setting potentially exposed to the agent/hazard. (2 points)
Sampling technique is used in the method. (3 points)
Analytical technique is used in the method. (3 points)
Hint: You should be able to show images of the occupational settings and what instruments are used for
sampling and analyzing which would help you describe it to your classmates. Make it a nice
presentation!
Page 1 of 1
Respirable Particulate
Method 1003
Date Issued: April 24, 2001
Analytes: Respirable Particulate, including Welding fume, Nuisance dust, Oil mist (mineral), and Particulate Not Otherwise
Regulated (PNOR)
NOTE: This method is not recommended for wood dust.
Summary: Polyvinyl chloride (PVC) filters are weighed and placed in cassettes. The samples are collected at 2.5 L/min using an
SKC aluminum cyclone. The filters are reweighed.
Sampling:
Sample Media: 5.0 µm low ash polyvinyl chloride filters (LA-PVC).
Use an SKC Aluminum cyclone.
Required Sampling Flow Rate:
2.5 L/min for SKC Aluminum cyclone
Sampling Time:
Maximum: 400 L
A Dorr-Oliver 10-mm nylon cyclone may be used but is not
preferable.
1.7 L/min for Dorr-Oliver cyclone
Minimum: 20 L
Sampling Procedure:
Sample at 2.5 L/min using an SKC Aluminum cyclone or 1.7 L/min for the Dorr-Oliver cyclone. At the specified flow rates, these
cyclones meet the OR-OSHA size selection criteria for crystalline silica. See Appendix A
Cassette Preparation:
Zero balance before each weighing. Handle filter using forceps. Pass filter over antistatic device and weigh to nearest microgram
(0.000001 g) using microbalance. Print filter weight and enter value into LIMS. Place filter on a support pad in three piece cassette
(use two piece cassette if sampling with a Dorr-Oliver cyclone) and compress cassette with vice. Cap ends of cassette. Place a
cellulose shrink band on cassette. Let cellulose shrink band dry before labeling cassette with date and filter type. Filters are good for
one year.
Sample Preparation:
Zero balance before each weighing. Disassemble cassette and using forceps, remove filter from cassette. Pass filter over antistatic
device and weigh to nearest microgram (0.000001 g) using microbalance. Print filter weight and enter value into LIMS.
Humidity: Criteria are 30 – 65 % RH.
If room humidity is outside of these criteria, do not weigh PVC filters.
Cassette Preparation Quality Control:
Follow same Quality Control procedures as when weighing samples.
Sample Weighing Quality Control:
• Weigh the 0.025 g or 0.020 g weight(s) on the microbalance before and after weighing filters. Record values in microbalance
weight book. Both weights should be within +/- 0.1% of expected weight.
• Reweigh at least one sample blank per analytical sample set and at least one in every twelve samples. Record both weights in
Microbalance Log Book. Both weights should be within +/- 0.030 mg of each other
• Weigh duplicate 5.0 µm PVC QC filters A and B and record weights in Microbalance Log Book. Acceptance Criteria is
calculated quarterly and recorded at top of log sheet.
Calculations:
mg sample − mgblank =
mgnet
3
= mg m
1000  Vol ( L)
Target concentration: 5 mg/m3, OSHA
References:
NIOSH 0600, Issue 3: 15 January 1998
OSHA PV2121, March 2003 (Sampling parameters, exposure limits)
Chemist: Kermit McCarthy
Document1
page 1of 2
Appendix A:
OSHA definition for Respirable Particulate as it relates to exposure to crystalline silica: (50 % less than 3.5 M)
Particle Aerodynamic
Diameter
(M)
2
2.5
3.5
5
10
Inhalable
Particulate Mass
(%)
90
75
50
25
0
ACGIH definition for Respirable Particulate: (50 % less than 4.0 M)
Particle Aerodynamic
Diameter
(M)
0
1
2
3
4
5
6
7
8
10
Inhalable
Particulate Mass
(%)
100
97
91
74
50
30
17
9
5
1
2

Purchase answer to see full
attachment

Place your order
(550 words)

Approximate price: $22

Calculate the price of your order

550 words
We'll send you the first draft for approval by September 11, 2018 at 10:52 AM
Total price:
$26
The price is based on these factors:
Academic level
Number of pages
Urgency
Basic features
  • Free title page and bibliography
  • Unlimited revisions
  • Plagiarism-free guarantee
  • Money-back guarantee
  • 24/7 support
On-demand options
  • Writer’s samples
  • Part-by-part delivery
  • Overnight delivery
  • Copies of used sources
  • Expert Proofreading
Paper format
  • 275 words per page
  • 12 pt Arial/Times New Roman
  • Double line spacing
  • Any citation style (APA, MLA, Chicago/Turabian, Harvard)

Our guarantees

Delivering a high-quality product at a reasonable price is not enough anymore.
That’s why we have developed 5 beneficial guarantees that will make your experience with our service enjoyable, easy, and safe.

Money-back guarantee

You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.

Zero-plagiarism guarantee

Each paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.

Free-revision policy

Thanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.

Privacy policy

Your email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.

Fair-cooperation guarantee

By sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.